MEDRAD® Centargo

MEDRAD® CENTARGO – DESIGNED FOR OPTIMIZING WORKFLOW
MEDRAD® Centargo simplifies workflow and provides efficiencies for radiology departments. MEDRAD® Centargo has been designed to automate parts of the workflow, allowing staff to spend more time with their patients.
HIGHLIGHTS OF THE MEDRAD® CENTARGO
Take a closer look at the features of the MEDRAD® Centargo that help in simplifying your CT suite.

WANT TO LEARN THE INS-AND-OUTS OF YOUR CT INJECTION SYSTEM?
Learn more about Components, Electrical, System capabilities, Accessories, and Ordering Information.

ENHANCE YOUR DAILY PRACTICE WITH BAYER
Ultravist® in combination with MEDRAD® Centargo supports you in achieving diagnostic image quality
Optimized Workflow

INCLUDES BUILT-IN WEIGHT-BASED DOSING ALGORITHM WITH KVP MODULATION

ONLY MULTI-PATIENT, PISTON-BASED CT INJECTOR IN CANADA CAPABLE OF REACHING 300 PSI

HAS 7 SENSORS AND AN AUTOMATIC AIR REMOVAL PROCEDURE

AUTOMATICALLY REFILLS RESERVOIRS AND PRIMES PATIENT LINES

CAN HELP SITES SAVE UP TO 23 MINUTES A DAY*
* CALCULATIONS ARE BASED ON A SITE THAT SCANS ON AVERAGE 30 PATIENTS PER DAY, FOLLOWING THE VALUES OUTLINED IN PERCENT STUDY.
SMART Protocols
CONTRAST ENHANCEMENT ISN’T ONE-SIZE-FITS-ALL
Patient weight plays a key role in how contrast media enhances images

46 KG PATIENT

67 KG PATIENT

132 KG PATIENT
Each scan used a standard 100 mL dose of contrast media. Images provided through the courtesy of the Medical University of South Carolina. Used with permission.
The same contrast media volume gives varying enhancement results depending on patient weight
For heavier patients, attenuation values may be below diagnostic levels
For lighter patients, attenuation may exceed required levels
STREAMLINE YOUR CT WORKFLOW WITH SMART PROTOCOLS
SMART Protocols enhances workflow efficiency through several key features:
Seamless Integration with RIS/PACS Platforms
** Do not configure contrast media with different active pharmaceutical ingredients (APIs) into the same contrast group as serious patient injury or death may result.
Small residual amounts of contrast media within the Day Set could lead to dose-independent reactions. Refer to the contrast media manufacturer’s package insert for specific indications and use time.

Contrast Enhanced Mammography
MEDRAD® CENTARGO – YOUR EFFICIENT PARTNER IN CE MAMMOGRAPHY
Contrast Enhanced Mammography is a fast-growing technique for breast cancer detection and diagnosis. It uses iodinated contrast media and dual energy digital mammography to produce a recombined image of the breast that shows areas of contrast enhancement.
The MEDRAD® Centargo helps technologists new to the practice of injecting contrast to navigate through a new workflow with ease. Through its user intuitiveness and automation of manual processes, MEDRAD® Centargo can help technologists streamline their workflow in busy breast assessment practices.

Service Offerings
WE’RE HERE TO HELP
We provide different service options that cater to your needs. Learn more about CT injector service offerings.